Buried Service Coating Texas

Cor-Pro Systems provides the top-of-the-line buried services coating in Texas and nearby Gulf Coast areas.

Several factors affect the longevity of a buried service.  These include quality of construction and protective coating systems, nature of the environment, operating conditions, and frequency and quality of maintenance, to name a few.

Among those mentioned the one factor that significantly affects the buried service long-term integrity is the effectiveness of its coating system.  Ruptures and leaks are a result of coating deterioration or failure.

In the 2000 estimate, about 24% of the 2.2 million miles of pipelines in the U.S. are more than 50 years old. This pipeline ageing results to deterioration and eventual damage.

Long-term integrity of buried pipelines relies on the effectiveness of buried services coating Texas.

Since 1985, Cor-Pro always over delivers by providing not only effective buried services coating management but also superior services by its highly trained engineers and personnel.

Cor-Pro remains the leader in corrosion protection methods in Texas and nearby Gulf Coast areas because they are reliable and dependable.

Learn more about Buried Services Coating Texas to aid you in choosing the appropriate corrosion system for your business.

External Coating For Buried Services

This section provides the standard practices for the selection, testing and evaluation, inspection, handling, storage, and installation of external coating systems for buried services.

External coating controls corrosion through isolation of the external surface of the buried service from the environment, to improve current distribution, and to lessen the cathodic protection current requirements.

To be achieve these functions, the buried services coating must be appropriately selected, handled, applied, and installed.

Buried services coatings Texas must have the following desirable characteristics:

  • Effective moisture barrier
  • Effective electrical insulator
  • Buried service application with minimal defects
  • Application can be through a method that does not alter the properties of the buried service
  • Must have good adhesion to buried service surface
  • Can resist development of holidays through time
  • Can maintain constant electrical resistivity with time
  • Can resist disbanding
  • Can withstand damage during handling, storage, and installation
  • Can repel chemical degradation
  • Must be able to retain physical characteristic
  • Offers ease of repair
  • Environmentally-friendly

Considerations For Buried Services Coating

Handling and Storage

For equipment applied with coatings before installation, personnel should be aware of the proper handling and storage to ensure that the buried services coating does not deteriorate.

Handling the equipment with the use of proper pads and slings can minimize damage.  Similarly, stored the buried services should have internal and external protection from atmospheric corrosion and coating deterioration.

Inspection

Buried services should have qualified personnel that ensure every phase of coating operation goes smoothly and that international guidelines and standard practices are in check.

Conformance to specifications must be periodically checked using appropriate testing procedures.  This should be present during surface preparation, primer application, coating thickness temperature, and bonding.

To determine coating flaws undetected visually, holiday detectors is highly recommended.  Operation of the holiday detectors must be in accordance with the manufacturer’s instructions and must be at a voltage level suitable to the electrical characteristics of the coating system used.

Installation

To maintain the corrosion protection of buried services during installation, tie-ins, joints, and fittings should use coatings with a material compatible with the existing coating.

Prior to installation, equipment should undergo inspection and defects, if any, should undergo repair using materials compatible with existing buried services coating.

Special consideration should also be in place for the ditch bottom, as it should be free of rock and other foreign materials that may cause external damage or electrical shielding.

Similarly, careful backfilling is highly recommended so that debris and rocks do not hit and damage the buried services coating.

Buried Services Coating Texas By Cor-Pro Systems, Inc

Cor-Pro Systems has advanced buried services coating management in Texas.  Some of the methods of surface preparation and coating application services include:

  • 1-Hour Cure Epoxies
  • Abrasive Blasting (complete line of abrasive media available)
  • Alternative profile achievement for areas not allowing blast
  • Enamels
  • Epoxy Coatings
  • High Temperature Coatings
  • Thermal-Cured Thin Film (Xylan, Ceramic Metallic, thin film Epoxy, Moly, etc.)
  • Urethane Coatings
  • Wear-Resistant Coatings
  • Zinc Primers

Aside from providing unparalleled corrosion protection management systems to its clients, Cor-Pro also delivers its services through Velocity Service.

Velocity Service is Cor-Pro’s commitment to its “Cor-Pro Gold Standard” of providing on-track delivery service.  Clients will get the best buried services coating management system within hours, not days.

About Cor-Pro Systems

With close to 30 years of dealing with various corrosion problems in several industries, Cor-Pro developed a keen eye in identifying crucial points in the corrosion process.  Due to this, the company can customize any corrosion protection system for each of their client.

To superiorly serve its clients and stakeholders, the company conducts further research and development relating to corrosion, its detrimental effects, and the cost-effective and environmentally safe method of mitigating it.

Through this, Cor-Pro continues to receive awards and certifications such as OHSAS 18001:2007 Occupational Health and Safety Management System and 18001:2007 and ISO 9001:2008 accreditations from Verisys Registrars.

Top Notch Buried Services Coating Texas Management Through Cor-Pro Systems, Inc.

If you have questions about our buried services coating Texas or want to get a custom quote for your particular corrosion protection need, contact us at 713-896-1091, or send us an e-mail at quotes@cor-pro.com.